Stainless Steel Woven Wire Mesh: Mesh Count, Wire Diameter and What to Specify

Stainless steel woven wire mesh is unsintered cloth. Stainless wire is woven so the openings are square or oblong. That is a different item from titanium woven mesh, from a nickel-mesh open-area calculation, from Dutch-weave filter cloth ordered as a filter medium, from a sintered laminate, and from a laboratory test sieve. A useful enquiry names the stainless grade, the mesh count, the wire diameter, the weave, and the opening already used on the drawing — or as many of those fields as you already have. This guide stays with unsintered stainless cloth in a plain or twill weave whose openings are square or oblong. It is not a second Dutch-weave article, not a sintered-laminate article, and not a list of stock rolls.

What this cloth is — and what it is not

Unsintered stainless woven cloth. HuiRui lists this construction on two product pages that are essentially the same listing, split by hole-size labels: stainless steel woven wire mesh (small hole) and stainless steel woven wire mesh (macropore). Both describe cloth woven from stainless steel wire into a square opening or an oblong opening. The listed process is weave. Size bands, mesh-count figures and grade lists on those pages are listings to confirm for a given order, not a frozen factory catalogue.

Not titanium woven mesh, and not a nickel-mesh method note. Titanium cloth is specified as titanium. It is not a stainless stand-in. See titanium woven wire mesh: mesh count, wire diameter and opening. The nickel mesh open area and porosity article is a method note for nickel mesh. It does not set the opening, the weave or the grade of a stainless cloth.

Not Dutch-weave filter cloth as the item being ordered. The same woven-mesh pages also list plain Dutch, twill Dutch and reversed Dutch among the weave options, and the FAQ short list names plain, twill and Dutch. Dutch weave is a different cloth: the counts and the wire diameters in the two directions are not the same, and a square-opening estimate does not rate it. If the drawing calls for Dutch weave, use Dutch weave mesh: warp, weft and what to specify and the unsintered listings for stainless steel Dutch weave wire mesh and stainless steel Dutch weave precision filter mesh. The remainder of this article stays with plain or twill cloth.

Not a sintered laminate. Sintering woven layers together produces a rigid stack, not a loose roll of cloth. When the fine layer is Dutch weave, see sintered Dutch weave mesh: layers, weave and what to specify. For a nickel stack specified layer by layer, see multilayer nickel sintered mesh. HuiRui also lists stainless steel sintered mesh; the fine layer of that laminate is not automatically Dutch weave. Say so if it must be.

Not crimped mesh as a second guide. On the stainless steel crimped mesh page, the wire is crimped before or as it is woven. That is a different construction. Name it if the drawing already calls for crimped wire. This article does not specify crimped screens.

Not a laboratory test sieve. Industrial woven cloth and test-sieve cloth are written to different documents, as set out below. Do not treat an industrial roll as a certified ISO 3310-1 test sieve.

Not fiber felt, perforated plate, expanded metal or foam. Those structures are not described by a woven mesh count in the sense used here. If the medium is a sintered fiber sheet, see stainless steel fiber felt.

A filter-support listing is a narrower starting point, not a second general catalogue. HuiRui also lists stainless steel wire mesh for filter support, with a shorter grade list (SS304 / SS316 / SS316L), a plain-weave note, and a table of mesh and wire starting points. Those rows belong to that page. They are not a catalogue for every stainless woven cloth on the general woven-mesh pages.

Grade: copy the designation already in use

The general woven-mesh pages list a long header and FAQ range: SUS/SS 201, 202, 321, 304, 304L, 316, 316L, 310S, 904L, 2205, 410, 430 and 2507. The body text on the same pages also names 304, 304L, 316, 316L and 430 as common materials. The filter-support page lists only SS304, SS316 and SS316L. Write the designation that is already on the drawing or in the material specification you use. Do not substitute 304 for 316 or 316L, or the reverse, and do not treat a listed stainless grade as interchangeable with nickel or titanium. This article does not assign a corrosion rate, a temperature limit, or an “always better” ranking to any grade.

Mesh count, wire diameter and the opening

Mesh count — also called mesh number — is the number of openings along a stated length. The FAQ on the general stainless woven-mesh pages defines mesh number as the number of holes per inch, and notes that, with the wire diameter held constant, a smaller mesh number corresponds to a larger aperture and a larger mesh number to a smaller aperture. Record the unit with the number. If the two directions do not share one count, write both. An oblong opening is not the same as a square opening described by a single count.

Wire diameter is the thickness of the wire that is woven into the cloth, given with units. A mesh count without a wire diameter does not fix the opening.

When the cloth is a regular square weave and both directions use the same round wire, a geometric estimate of the clear opening, in millimetres, is 25.4 divided by the mesh count, minus the wire diameter in millimetres. That figure has to come out greater than zero. A zero or negative result means that particular count and diameter cannot form a square opening of this model. The estimate is a geometry check only. It is not an inspection certificate, not a test-sieve designation, and not a filtration rating. Dutch weave, warp and weft that are not equal, oblong openings, or cloth that has been coated or deformed after weaving need a description of their own; do not force them through this square-opening estimate.

ISO 4783-2 is a guide to preferred aperture-size and wire-diameter combinations for woven wire cloth, for aperture sizes from 16 mm to 0.02 mm. The official public abstract states that the cloth is designated, in this order, by width of aperture, diameter of wire, material of wire, and type of weave. ISO 4783-1 is the general list from which such preferred groups may be chosen; that part also states the percentage open area of each combination and uses the same designation order (aperture width, wire diameter, material, and type of weave or type of crimp). If the drawing already names an aperture and a wire diameter in that order, transcribe them. Do not invent an open-area percentage for a HuiRui listing that does not give one, and do not treat a preferred-combination table in a standard as a HuiRui stock list.

The general woven-mesh pages list a width band of 0.05–3.5 m and a length band of 1–210 m. A later note on the same pages gives a standard roll length of 30 m and widths of 1 m, 1.2 m, 1.5 m, 2.0 m and similar; treat that note as a listed example, not a promise that those rolls are in stock. The header mesh-number listing is 1–3000; a later note on the same pages says “1 mesh to 3200 mesh.” Those two figures do not agree. This article does not choose one as “the HuiRui range.” The count that applies to a given order must be confirmed.

The filter-support page lists starting points in a mesh and wire table (plain weave; SS304 / SS316 / SS316L): 40×36 mesh, 0.20–0.25 mm; 40 mesh, 0.20–0.25 mm; 80 mesh, 0.12–0.16 mm; 100 mesh, 0.10–0.12 mm; 150 mesh, 0.06–0.07 mm; 200 mesh, 0.05–0.06 mm; 300 mesh, 0.035–0.04 mm; 400 mesh, 0.025–0.03 mm. That page also lists a usual width band of 0.5–1.5 m, says other widths can be made, and offers the cloth in rolls or as cut sheets. Those rows are starting points on that page only. They are not a substitute for naming the cloth you actually need, and they are not a table for the general woven-mesh pages, which do not publish a mesh-versus-wire catalogue.

Weave, industrial cloth and test sieves

Plain weave and twill weave are the usual constructions for square or oblong openings. The general pages also list five-heddle and three-heddle weaves. If the drawing already names one of those, write it; this article does not turn those names into a second specification guide. If the weave is Dutch — plain Dutch, twill Dutch or reversed Dutch — leave this article and use the Dutch-weave guide.

ISO 9044:2016 defines terms for industrial woven wire cloth used for screening, and it sets maximum permissible error, requirements and test methods. On the official public abstract, it applies to industrial woven wire cloth with square apertures, made of steel, stainless steel or non-ferrous metals (see ISO 4783-2). It does not apply to cloth coated after weaving, and it does not apply to pre-crimped and welded wire screens, which are covered in other documents named in that abstract (ISO 4783-3 and ISO 14315). The abstract also notes limited application to woven wire cloth used for purposes other than screening, in which case other requirements may be agreed between purchaser and supplier when the order is placed. If your duty is screening with a square-aperture stainless cloth, ISO 9044 is the industrial-cloth document to name when you already work to it. If the cloth is coated after weaving, or the wire is pre-crimped, say so; do not assume ISO 9044 covers those forms. The 2016 edition remains the published current text (confirmed in 2021; a later systematic review was under way on the official catalogue page when this article was prepared).

ASTM E2016-22 is the Standard Specification for Industrial Woven Wire Cloth. The official public scope covers industrial woven wire fabric, referred to as wire cloth, for general use including the separation of particles, made of any primary metal or metal alloy wire suitable for weaving. It does not apply to filter cloth or Dutch weave, fourdrinier and cylinder cloth, galvanized hardware cloth, insect wire screening, spiral weave wire cloth, testing sieve cloth, or welded wire cloth. That exclusion is the reason a Dutch-weave requirement, or a test-sieve requirement, should not be written as a generic E2016 mesh-count order.

Laboratory test sieves are specified separately. ISO 3310-1:2016 covers technical requirements and test methods for test sieves of metal wire cloth, for aperture sizes from 125 mm down to 20 µm, in accordance with ISO 565. An industrial screening cloth supplied as a roll is not, by itself, a certified test sieve. If the purchase order actually requires a test sieve, name ISO 3310-1 or the test-sieve specification you already use, and do not rate a HuiRui industrial cloth as a sieve by copying an aperture series from that standard.

What to put on the enquiry

Construction. State that the item is unsintered stainless woven cloth, in a plain or twill weave, with a square or oblong opening — not Dutch filter cloth, not a sintered laminate, not a test sieve, and not crimped mesh unless that is what the drawing already calls for.

Grade. Copy the designation already on the drawing. Do not swap 304 and 316/316L.

Cloth geometry. Mesh count, with the unit and both directions if they differ; wire diameter, with units; the weave; and the opening or aperture you already work to, saying whether it is a geometric check or a measured value.

Finished size. Width and length, roll or cut sheet, or a drawing, and the quantity.

Any standard already cited. If the enquiry already names ISO 9044, ASTM E2016, or another cloth document, transcribe the designation exactly. Do not treat a product-page listing as that acceptance.

Nearby forms

Form What it is Specify first
Stainless woven cloth Unsintered stainless wire woven to a square or oblong opening Grade, mesh count, wire diameter, weave, opening and cut size
Dutch weave cloth Unsintered filter cloth with unequal warp and weft Both counts and both wire diameters; plain or twill Dutch (43519)
Sintered Dutch weave Bonded laminate whose fine layer is Dutch weave Layer stack, fine cloth, metal and finished form (43530)
Nickel sintered mesh Sintered stack of woven nickel meshes Layers and mesh count per layer (43513)
Filter-support listing A narrower plain-weave stainless listing with a mesh/wire table Treat the table as starting points on that page only
Crimped mesh Wire is crimped before or as it is woven Name the crimped construction (product page)
Titanium woven mesh Titanium wire cloth, not stainless Grade, count, diameter, weave and opening (43415)
Nickel open-area note A method note for nickel mesh, not a stainless cloth guide Open-area or porosity method (21806)

A square-opening estimate is not a Dutch-weave rating, not a sintered-laminate rating, and not a test-sieve designation.

What to send for a quote

A first message can be short. A sketch, a mesh count and wire diameter already in use, or a cut size is enough to open a HuiRui enquiry. When some of the following details are already known, include them:

  1. That the item is unsintered stainless woven cloth (plain or twill; square or oblong opening), not Dutch filter cloth, a sintered laminate or a test sieve, unless one of those is what you actually need.
  2. The stainless designation already on the drawing; do not swap 304 and 316/316L.
  3. Mesh count with its unit (both directions if they differ), wire diameter with units, and the weave.
  4. The opening or aperture you already work to, and whether it is a geometry check or a measured value.
  5. Width and length, roll or cut sheet, or a drawing, and the quantity.
  6. Any cloth standard already cited (for example ISO 9044 or ASTM E2016), copied exactly, or a reference sample.

Enquiries for this construction are reviewed against the small-hole and macropore stainless woven-mesh listings. Grade, mesh count, wire diameter, weave, opening and finished size are confirmed per enquiry. Nearby constructions are covered on the Dutch weave specification guide, the sintered Dutch weave guide, the filter-support listing and the crimped mesh page. Product-page marketing and the standard scopes above are not a guaranteed result for every roll or cut. Include the drawing plus the particulars already known, and we will confirm what can be supplied.

References

Contact us Form

Leave us a message — we’ll reply within 30 minutes!
Please feel free to leave your message here, or send an email to tzx@nickelfoam.com

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Start typing to see products you are looking for.

Contact us

Leave us a message — we’ll reply within 30 minutes!
Please feel free to leave your message here, or send an email to tzx@nickelfoam.com

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

*We respect your confidentiality and all information are protected.

Contact us

Leave us a message — we’ll reply within 30 minutes!
Please feel free to leave your message here, or send an email to tzx@nickelfoam.com

"*" indicates required fields

This field is for validation purposes and should be left unchanged.

*We respect your confidentiality and all information are protected.